Your gas furnace won’t run in a power outage. It takes very little to fix that.

The gas keeps flowing when the lights go out. The furnace quits anyway, because its fan and controls run on electricity.

Illustration

In short: A gas furnace fan needs roughly 300 to 875 watts to run. An electric heat strip needs about 10,000. Keeping a gas-heated house warm in an outage means running one fan, not the whole house.

By Bret, founder of Powerhouse Pergola, on the Outer Banks of North Carolina

On Sunday, January 25, 2026, an ice storm that reached from New Mexico to New England left nearly 1 million customers across the South without power. In Tennessee more than 316,000 lost power, and restoring it was expected to take days. Then the cold moved in behind the storm.

Every gas furnace in those homes went quiet with gas still in the line, unless the house had backup power. The burner makes the heat. The fan that pushes warm air through the house, the igniter that lights the burner and the controls that run it all need electricity.

How little it takes

The fan is nearly the whole load. Honda’s generator wattage guide and a Massachusetts state generator chart list the same figures for a gas or oil furnace fan: 300 watts running for a 1/8 horsepower motor, up to 875 watts for the largest size they list.

Compare that with electric heat. A single 10-kilowatt electric heat strip draws about 10,000 watts, more than 11 times the largest fan on those charts.

So keeping a gas-heated house warm is a job for a portable generator, the outlet on a hybrid or electric truck, or a battery power station (often sold as a “solar generator”). You are not trying to run the whole house. You are running one fan. Heat that stays on is also what keeps the pipes from freezing.

Two things to check first:

  • The starting surge. A motor needs a short burst of extra power to get going. The same charts put it at 500 to 2,350 watts. Your power source has to cover that burst, not just the running number.
  • Your own furnace. The rating plate is usually inside the blower door. If it lists amps, multiply by 120 for a top-end figure in watts.

How long a battery lasts

The fan only runs while the furnace is heating, so the number that matters is hours of fan, not hours in the day. A kilowatt-hour is 1,000 watts used for one hour. A 500-watt fan that runs a total of 8 hours in a day uses 4 kilowatt-hours, and one that runs 4 hours uses 2.

For a battery, divide its usable watt-hours by the fan’s watts. A 2,000 watt-hour power station gives a 500-watt fan about 4 hours of run time. A lower thermostat setting means the fan runs fewer hours, so the same battery lasts longer. Try your own numbers in the backup power calculator.

Hooking it up the safe way

A furnace is wired straight into the house. It has no plug. The safe connection is a transfer switch or an approved interlock, installed by a licensed electrician. A transfer switch lets a circuit take power from the utility or from your backup source, never both at once. That keeps your backup power from flowing out onto the utility lines, where it can injure the crews restoring service. Never feed a house through a wall outlet.

A generator stays outside, at least 20 feet from the house, with the exhaust pointed away. It never runs in a garage, on a porch or under a carport. The Consumer Product Safety Commission estimates that carbon monoxide from portable generators kills nearly 100 people a year. Put carbon monoxide alarms with battery backup on every level of the house, and keep snow cleared from the furnace’s outdoor vents.

What this does not fix

Heat pumps and electric furnaces make their heat with electricity, so they need far more than a fan’s worth. In a house with both a heat pump and a gas furnace, the gas furnace is the side to power in an outage.

Test it before the storm

Some gas furnaces will not stay lit on a portable generator or a battery power station, even though the fan runs. It is far better to find that out on a calm day than in an ice storm.

Why it happens. A furnace proves its flame is lit by passing a tiny electric current through the flame to the furnace’s grounded metal. Lennox’s service literature describes it that way, and says the control checks for a proper ground before it will go on with the heating sequence. That check needs the neutral wire and the ground wire to be tied together at one point. On utility power, that point is the main electrical panel in your house. Many small generators are built without that tie. Honda’s manual says the ground system on its portable generators is not connected to the neutral. Generators and power stations come both ways, and you cannot tell from the box.

What that means for you. When the furnace is fed through a switch at the house panel, the panel’s own tie usually does the job, as long as the switch and the generator are matched to each other. That matching is the electrician’s job. When the furnace is run by a cord straight from a generator or a battery, it may light and then shut off a few seconds later.

Two more things that stop a furnace. If the hot and neutral wires are swapped anywhere along the way, the control will not run the heating sequence. And if the voltage sags, which a long thin extension cord can cause, the control will ignore the call for heat. Owners also report that some furnaces object to the rougher power from big open-frame generators.

What not to do. Do not fix this with an adapter plug that ties neutral to ground because a video said so. In the wrong setup that creates a shock hazard. It is an electrician’s decision, not a hardware-store one.

The test. Tell the electrician exactly which generator or battery you plan to use. Then, with that same generator and that same cord, run the furnace through a whole heating cycle. It should light, stay lit, bring the fan on, run for several minutes and shut down normally. Do it once on a mild day and once on a cold morning.

Better yet, make it part of a full dress rehearsal for the whole house.

One thing to do today

Open the blower door on your furnace and write down the amps on the rating plate. Multiply by 120. That is the most your furnace will ask of a backup source.

The numbers

WhatFigure
Gas furnace fan, running300 to 875 watts
Gas furnace fan, starting500 to 2,350 watts
10 kW electric heat stripAbout 10,000 watts
500-watt fan, 8 hours of run time4 kilowatt-hours
Generator distance from the houseAt least 20 feet
Deaths from portable generator carbon monoxideNearly 100 a year (CPSC, January 2024)
Customers without power across the South, evening of Jan. 25, 2026Nearly 1 million

For reporters

Use the numbers and quote this piece freely. All we ask is a link back to this page. To reach us, use the form at Join the waitlist.

Sources

More from Before the Storm →

Tell us about your place

Say what you want to build, or what you want to keep running when the power is out. We’ll tell you straight what it would take.